Calmet - Smart Calibration Devices

Smart Calibration Devices

NEW WWW:


WWW.CALMET.COM.PL

Calmet - Kalibratory, testery, mierniki i analizatory PL   Calmet - Calibrators, testers, meters and analysers GB   Calmet - Калибраторы, тестеры и анализаторы RU   Calmet - Kalibratoren, Tester, Messgeräte und Analysatoren DE   Calmet - Calibrateurs, testers, appareils de mesure et analyseurs FR   Calmet - Calibradores, testadores, medidores e analisadores PT   Calmet - Calibradores, testadores, medidores y analizadores ES 
Home page
Products
Laboratory
Download
About us
Contact


TOP products:



Products by category:

 .: TE30 - Portable Three Phase Working Standard and Power Quality Analyzer

TE30

Portable Three-Phase Working Standard and Power Quality Analyzer


TE30 - Three-Phase Working Standard and Power Quality Analyzer





Data sheet





Overview
Features Application Software Resources Equipment FAQ

TE30 Portable Three-Phase Working Standard uses large 7 inch LCD display with touch panel for setting and presenting measurements. TE30 is able to save measurement data on SD card, save a BMP screen capture and print measurement report directly to Bluetooth printer. Analyzer can be also connected by USB, Bluetooth or LAN with PC computer or Tablet and setting by TE30 PC Soft.



Three-Phase Power Network Analyzer

TE30 Analyzer is used to measure and refresh all power network parameters in real time. Data can be displayed in four different ways: table, vectors diagram, oscilloscope diagram and harmonics in bar and table format.

ENLARGE: TE30 Three Phase Working Standard table display

Table Display function is used for indicating all relevant parameters of three phase power network. The actual value of parameter helps to analyse circuit condition like: voltage missing, current missing, current reversal, asymmetry, etc.
ENLARGE: TE30 Three Phase Working Standard vectors display

Vectors Display function is used for verification of power network wiring and meter connection. Three orientation of vectors can be chosen.
Additionally the voltage unbalance (voltage asymmetry), phase sequence, neutral voltage and neutral current is calculated.
ENLARGE: TE30 Three Phase Working Standard oscilloscope display

Oscilloscope Display function is used for displaying the waveform of voltage and current change in time. Six parameters and 1, 2 or 4 periods can be displayed at the same time (picture presents an example waveform of 1-phase Switching Power Supply input voltage and current).
ENLARGE: TE30 Three Phase Working Standard harmonic measurement bar

ENLARGE: TE30 Three Phase Working Standard harmonic measurement table

Harmonic Measurement function is used for measuring amplitude and phase of harmonic in voltage, current, active power and reactive power up to 63st harmonic. The measured harmonic can be displayed in tabular and bar format. Total harmonic distortion THD, total distortion factor TDF, crest factor CF, total interharmonic distortion TID will be displayed as additional information about a form of analysed voltage and current.

Back to top



Energy Meter Tester

TE30 Tester offers automatic and easy to use function for energy meter testing. TE30 can be used to test error, test register and Pmax test directly on site with used load. All functions can measure energy for active, reactive and apparent power P, P+, P-, Q, Q+, Q-, S and energy for the first harmonic of active and reactive power PH1, PH1+, PH1-, QH1, QH1+, QH1-.

ENLARGE: TE30 Three Phase Working Standard meter error test

Meter error calculating (partial errors, average error, standard deviation) directly in [%] with:
- method of settings time of measurements or number of impulses,
- automatic identification meter constant,
- automatic determining measurement time or number of pulses.
ENLARGE: TE30 Three Phase Working Standard register testing

Register testing for calculating of register error directly in percentage. Three registers can be verified at the same time and any combination of measured power can be chosen.
ENLARGE: TE30 Three Phase Working Standard maximum power

Maximum power measuring for testing of maximum power (demand) meters.
Measurement data can be visualized in form of trend chart or table and are easy to save, read in the future and print.

ENLARGE: TE30 Three Phase Working Standard meter error trend  ENLARGE: TE30 Three Phase Working Standard meter error table

Back to top



Instrument Transformer Tester

TE30 Tester can be used for automatic testing instrument transformers like LV and MV current CT and potential PT (VT) directly on site.

ENLARGE: TE30 Three Phase Working Standard burden test

Burden Test function is used for calculating of current transformer CT and potential transformer PT burden directly in percentage (Percent Nominal Load) simultaneously in three phases.

Calculating of phase shift of load is enable.

For easiest measurements, data from calculation of wiring and fuse resistance can be included into burden error.
ENLARGE: TE30 Three Phase Working Standard CT ratio test

CT Ratio Test function is used for calculating of current transformer CT ratio and phase shift error directly in percentage simultaneously in three phases.

PT Ratio Test function is used for calculating of potential transformer PT ratio and phase shift error directly in percentage simultaneously in three phases.

Back to top



Power Quality Analyzer IEC 61000-4-30

For easy real time measurements of power quality a standard function Power Network Analyzer can be useful.

Additionally special function Trend Chart Display can easy visualize of measurement result in real time mode.

ENLARGE: TE30 Three Phase Working Standard trend chart display

Trend Chart Display function is used for displaying the changes in time of all relevant parameters of three phase power network.

Analyser can store all parameters averaged in 1-100 seconds step time.

User can display simultaneously up to 3 trend charts of any stored parameters.
For advanced and long term analyse of power quality TE30 offers a Recording function.

ENLARGE: TE30 Three Phase Working Standard - recording parameters

ENLARGE: TE30 Three Phase Working Standard - recording mode

ENLARGE: TE30 Three Phase Working Standard - recording analysis

Recording function is used for registration of all network parameters and additionally for measure dips, swells, interruptions, interharmonics, signal voltages and flicker.

Data with time stamp are stored in the SD card (up to 32GB) for archive and further analyse in TE30 PC Soft program. It is able to check for EN 50160 compatibility or for individual users requirements.

Back to top


Visit Calmet - Smart Calibration Devices on   Facebook    Youtube