TE30
Portable Three-Phase Working Standard and Power Quality Analyzer
Electricity meters tester class 0.05% and 0.1%. Three phase tester of current transformers and analyser of power network quality. It makes possible electricity meters testing on the site or in the laboratory.
TE30 is our newest universal 4-in-1 device combining functions of:
- Three-Phase Power Network Analyzer (Basic function)
- Energy Meter Tester (Basic function)
- Instrument Transformer Tester (Basic function)
- Power Quality Analyzer (REC function)
TE30 Working Standard is a continuation of Calport 100 (Three-Phase Power Network Analyzer - our bestseller since 1999) and NSQ400 (high performance Power Quality Analyzer).
In one case, TE30 can offer all you need and more:
- High accuracy: three-phase working standard class 0.05%
- Wide input ranges: 0.05-600V and 0.001-12A (up to 40kV and 3000A with clamps)
- Quick measurements, analysis and reports of ALL power quality parameters
- Automatic tests of energy meters and PT (VT), CT transformers
- Easy to carry, strong and waterproof (IP67) transportation case for TE30 with accessories, ready to use on site just after opening the cover
- Professional service and support (it doesn't matter if you have a complex or trivial issue)
- Low price in comparison to the best performance
Read the Data sheet and the rest of the website to know all functions of the TE30 Working Standard. You will find there information about:
Measurement function:
- electrical parameters displaying in table, vector, oscilloscope, bar and trend chart format
- energy meter testing of meter error, register and maximum power with all type of pulse outputs (disc mark, LED, LCD, S0)
- three-phase CT and PT (VT) transformers testing of ratio, phase shift and burden with easy wiring resistance calculation
- measuring up to 63rd harmonics and interharmonics
- calculating all type of active, reactive and apparent energy: P, P+, P-, Q, Q+, Q-, S, PH1, PH1+, PH1-, QH1, QH1+, QH1-
- recording and power quality analysis according to IEC 61000-4-30: dips, swells, interruptions, signal voltages, voltage unbalance, flicker
Other advantages:
- independent electronic compensated clamps allow calibration, service, later purchase without factory return of the device and interchange of clamps between different TE30 Working Standard
- powering from: line 50-450V AC/DC or battery up to 2 hour lifetime
- light weight: 2kg (4.4lbs) with batteries
- large 7″ 800x480 LCD colour display with touch screen easy to use with gloves
- screen capture and screen printing function
- USB, Ethernet and Bluetooth interface for printer, PC computer, tablet or Internet communication
- up to 32GB SD memory card for data
- measurement reports and printscreens printing on site by the wireless printer
- context help with circuit diagrams
- impulse input and output up to 200kHz with automatic constants calculating in imp/kWh, imp/Wh, Wh/imp and Hz in all type of powers
- system configuration can be update at any time
- optionally external GPS modem synchronization
- producer warranty
- Calibration Certificate
TE30 Portable Three-Phase Working Standard uses large 7 inch LCD display with touch panel for setting and presenting measurements. TE30 is able to save measurement data on SD card, save a BMP screen capture and print measurement report directly to Bluetooth printer. Analyzer can be also connected by USB, Bluetooth or LAN with PC computer or Tablet and setting by TE30 PC-Soft.
TE30 is an universal device and can be used as a:
- Three-Phase Power Network Analyzer
- Energy Meter Tester
- Instrument Transformer Tester
- Power Quality Analyzer IEC 61000-4-30
Three-Phase Power Network Analyzer
TE30 Analyzer is used to measure and refresh all power network parameters in real time. Data can be displayed in four different ways: table, vectors diagram, oscilloscope diagram and harmonics in bar and table format.
Energy Meter Tester
TE30 Tester offers automatic and easy to use function for energy meter testing. TE30 can be used to test error, test register and Pmax test directly on site with used load. All functions can measure energy for active, reactive and apparent power P, P+, P-, Q, Q+, Q-, S and energy for the first harmonic of active and reactive power PH1, PH1+, PH1-, QH1, QH1+, QH1-.
Instrument Transformer Tester
TE30 Tester can be used for automatic testing instrument transformers like LV and MV current CT and potential PT (VT) directly on site.
Power Quality Analyzer IEC 61000-4-30 (REC function)
For easy real time measurements of power quality a standard function Power Network Analyzer can be useful.
Additionally special function Trend Chart Display can easy visualize of measurement result in real time mode.
TE30 PC-Soft
The TE30 PC-Soft is a powerful software to expand capabilities of TE30 device of remotely connecting to device via USB, Bluetooth or Ethernet and enable use of a full array of testing and analysis. Software is dedicated for PC computers with Windows 2000/XP/Vista/7/8/10 and tablets with Windows 8.1/10.
- The TE30 PC-Soft is used to remote control and monitor of the device and allows to:
- measuring and recording of all three phase power network parameters with digital, graph and oscilloscope display,
- verification of power network wiring with measure and recording of power network parameters by displaying of: three phase voltage and current vector, neutral voltage and current vector, direction of vector rotation,
- testing of electricity meters directly on site,
- testing of LV and MV current CT and potential PT transformers simultaneously in three phases directly on site,
- measuring of power quality parameters according to IEC 61000-4-30,
- store, export to MS Excel, copy to system clipboard and print the result of measurements and tests.
TE30 set's:
Optional accessories:
REC function - Recording of power network parameters Extending the TE30 functionality with recording of power network parameters. The recorded parameters can be chosen individually or automatically acc. to EN 50160 standard. |
||
CF106 - Universal scanning head Universal miniature scanning head for detecting (counting) impulses from inductive, LED and LCD energy meters. Additionally it enables counting of manually triggered impulses (Start/Stop push button function). Sometimes (when access is difficult) it is the only way to count pulses from inductive, LED and LCD meters. It can be easy mounted to meter by holder (CF106H option) or by self adhesive Velcro and it can also work by hand without mounting to meter.holder. |
||
DR200D - Printer Miniature thermal printer with Bluetooth and accumulator. |
||
EA34 - Set of safety measurement cables 10pcs of cables for voltage and current. |
||
EA20 - Additional accessories for safety cables up to 20A Additional accessories (handlers and terminals) for safety cables. It makes possible comfortable connecting to conductor rails of checked site. |
||
CT10AC - Electronic compensated clamps 12A Miniature, electronic compensated clamp for measuring current up to 12A (1 set). |
||
CT100AC - Electronic compensated clamps 120A Miniature, electronic compensated clamps for measuring current up to 120A (1 set). |
||
CT1000AC - Electronic compensated clamps 1200A Electronic compensated clamps for measuring current up to 1200A (1 set). |
||
FCT3000AC.B - Flexible electronic compensated clamps 3000A Flexible clamp for measuring current in ranges 30/300/3000A in hard to reach places, (1 set). |
||
ALW2000AC.1 - primary current sensors 2000A 2000A (at 40kV) primary current sensors for LV and MV nets, recognized and used by many reputable manufacurers. |
||
VLW40kVC.1 - primary voltage sensors 40kV 40kV primary voltage sensors for MV nets. |
||
CC11 - Single phase AC current source Single phase AC current source class 0.2 with signal frequency equal to 50/60Hz and with phase shift 0° or 180° relative to the supply voltage. The CC11 enables to generate current in range up to 5A at the supply voltage 85..264V. |
||
EL10 - Phantom load The EL10 is single phase AC current source and is used to force the current flow up to 5A through current coils of meters without necessity to disconnect tested meter |
||
ET30 - Large transportation case
|
||
ET31 - Medium transportation case
|
||
ET32 - Small transportation case
|
||
AD100EXT - Powering extension Extension for powering TE30 from measurement network. |
||
Rechargeable battery NiMH AA R6 1.2V 2700mAh (5pcs). |
Optional software:
FAQ - Frequently Asked Questions:
- What will be the 1mA current measurement accuracy of direct current inputs?
- I often test energy meters on very distorted power network. It is possible to find the source of the distortions?
- Can I use TE30 to test the ratio of MV (15kV) current transformer?
- Error test of three-phase energy meter goes 33%. What is wrong?
- We should be done to use the REC functionality (network parameters recording) of the TE30 tester?
- What are the main differences between the TE30 and TE30 Lite?
1. What will be the 1mA current measurement accuracy of direct current inputs?
The accuracy of the TE30 (class 0.05%) is defined as 0.05% of measurement value in range 10mA...12A and 0.05% of lower range (10mA) for values below 10mA.
It gives: 0.05%*10mA=0.005mA. For 1mA the relative error is: (0.005mA/1mA)*100%=0.5%. So the 1mA is measured with 0.5% of accuracy for TE30 class 0.05%.
2. I often test energy meters on very distorted power network. It is possible to find the source of the distortions?
Yes, it is easy by the unique function of power (P,Q) harmonic measurements.
The sign at the bars of power in spectrum diagram shows source of the distortion.
For the active power harmonics (P): if plus (+) then distortion goes from network to load; if minus (-) then distortion goes from load to network.
See the pictures below. Oscilloscope shows that U and I are highly distorted but only harmonics of power P with many long minus bars means that distortion goes from this customer to power network.
3. Can I use TE30 to test the ratio of MV (15kV) current transformer?
Yes, you can use special High Voltage current clamps up to 2000A at 40kV called AmpLiteWire, connected to the primary side of CT. The secondary side of CT can be connected directly to the TE30 current inputs or by precision 100A clamps to avoid breaking of the secondary current circuit. As the result you will get the ratio and phase shift error of the MV CT.
4. Error test of three-phase energy meter goes 33%. What is wrong?
Approximately 33% or 66% meter error test result means that there is a wiring problem.
At first make sure that TE30 voltage and current inputs are connected correctly to network/meter. Then use a Vector Graph measurements to find the problem. Probably one phase in your meter is disconnected/shorted or rotated.
Typical Vector Diagram shows picture below.
5. What should be done to use the REC functionality (network parameters recording) of the TE30 tester?
To use the REC functionality, user need to purchase a license key that extends the TE30 functionality with the REC function, enabling the measurement, registration and analysis of power quality parameters. The license key generated remotely by the manufacturer and can be uploaded by the user at any time after purchasing the device or by manufacturer when purchasing the TE30. Recorded parameters can be selected individually or automatically in accordance with the requirements of EN 50160.
6. What are the main differences between the TE30 and the TE30 Lite?
The TE30 Portable Three-Phase Workiing Standard and Power Quality Analyzer is manufactured in the 0.1% or 0.05% class, while TE30 Lite Portable Three-Phase Working Standard and Power Quality Analyzer is available in the 0.2% class.
The TE30 Portable Three-Phase Working Standard and Power Quality Analyzer enables direct current measurement up to 12A, while TE30 Lite enables current measurement up to 3000A with clamps only (depending on the selected optional measuring clamps).